View Issue Details[ Jump to Notes ] | [ Issue History ] [ Print ] | |||||||
ID | ||||||||
0021230 | ||||||||
Type | Category | Severity | Reproducibility | Date Submitted | Last Update | |||
defect | [Openbravo ERP] 07. Sales management | major | have not tried | 2012-07-27 10:32 | 2012-08-01 11:00 | |||
Reporter | mtaal | View Status | public | |||||
Assigned To | mtaal | |||||||
Priority | normal | Resolution | fixed | Fixed in Version | 3.0MP14 | |||
Status | closed | Fix in branch | Fixed in SCM revision | 7f16a6a46998 | ||||
Projection | none | ETA | none | Target Version | 3.0MP14 | |||
OS | Any | Database | Any | Java version | ||||
OS Version | Database version | Ant version | ||||||
Product Version | SCM revision | |||||||
Merge Request Status | ||||||||
Review Assigned To | ||||||||
OBNetwork customer | No | |||||||
Web browser | ||||||||
Modules | Core | |||||||
Support ticket | ||||||||
Regression level | ||||||||
Regression date | ||||||||
Regression introduced in release | ||||||||
Regression introduced by commit | ||||||||
Triggers an Emergency Pack | No | |||||||
Summary | 0021230: Pick & Execute Windows:Change reference of read only fields to not do combo value computation by FIC | |||||||
Description | P&E windows have many fields which are read only but which are defined as tabledir. The FIC will compute the combo content for these fields without correct filtering potentially reading huge amounts of data. For read only fields no tabledir should be used for P&E windows. Change check the following windows: "RFC Order Pick / Edit Lines" "RM Shipment Pick and Edit" "RM Receipt Pick and Edit" "Modify Payment In Plan" "Modify Payment Out Plan" | |||||||
Steps To Reproduce | . | |||||||
Tags | No tags attached. | |||||||
Attached Files | ||||||||
![]() |
||||||||
|
![]() |
|
(0050954) hgbot (developer) 2012-07-27 16:54 |
Repository: erp/devel/pi Changeset: 7f16a6a46998e2d1fdfe35f600283fa84506edf6 Author: Martin Taal <martin.taal <at> openbravo.com> Date: Fri Jul 27 16:53:37 2012 +0200 URL: http://code.openbravo.com/erp/devel/pi/rev/7f16a6a46998e2d1fdfe35f600283fa84506edf6 [^] Fixes issue 21230: Pick & Execute Windows:Change reference of read only fields to not do combo value computation by FIC Changed the reference of the storage bin to a selector and of several other columns to search: m_inout_id column, order line column --- M src-db/database/sourcedata/AD_COLUMN.xml --- |
(0050967) hudsonbot (viewer) 2012-07-28 01:24 |
A changeset related to this issue has been promoted main and to the Central Repository, after passing a series of tests. Promotion changeset: https://code.openbravo.com/erp/devel/main/rev/c6491bd9e10b [^] Maturity status: Test |
![]() |
|||
Date Modified | Username | Field | Change |
2012-07-27 10:32 | mtaal | New Issue | |
2012-07-27 10:32 | mtaal | Assigned To | => mtaal |
2012-07-27 10:32 | mtaal | Modules | => Core |
2012-07-27 10:32 | mtaal | OBNetwork customer | => No |
2012-07-27 16:33 | mtaal | Summary | Pick & Execute Windows:Change reference of sales order line and m_inout_id to search to prevent FIC from assuming it is a combo => Pick & Execute Windows:Change reference of read only fields to not do combo value computation by FIC |
2012-07-27 16:33 | mtaal | Description Updated | View Revisions |
2012-07-27 16:53 | mtaal | Relationship added | related to 0020955 |
2012-07-27 16:54 | hgbot | Checkin | |
2012-07-27 16:54 | hgbot | Note Added: 0050954 | |
2012-07-27 16:54 | hgbot | Status | new => resolved |
2012-07-27 16:54 | hgbot | Resolution | open => fixed |
2012-07-27 16:54 | hgbot | Fixed in SCM revision | => http://code.openbravo.com/erp/devel/pi/rev/7f16a6a46998e2d1fdfe35f600283fa84506edf6 [^] |
2012-07-28 01:24 | hudsonbot | Checkin | |
2012-07-28 01:24 | hudsonbot | Note Added: 0050967 | |
2012-08-01 11:00 | marvintm | Status | resolved => closed |
2012-08-01 11:00 | marvintm | Fixed in Version | => 3.0MP14 |