Openbravo Issue Tracking System - Openbravo ERP
View Issue Details
0021230Openbravo ERP07. Sales managementpublic2012-07-27 10:322012-08-01 11:00
mtaal 
mtaal 
normalmajorhave not tried
closedfixed 
5
 
3.0MP143.0MP14 
Core
No
0021230: Pick & Execute Windows:Change reference of read only fields to not do combo value computation by FIC
P&E windows have many fields which are read only but which are defined as tabledir. The FIC will compute the combo content for these fields without correct filtering potentially reading huge amounts of data.

For read only fields no tabledir should be used for P&E windows.

Change check the following windows:
"RFC Order Pick / Edit Lines"
"RM Shipment Pick and Edit"
"RM Receipt Pick and Edit"
"Modify Payment In Plan"
"Modify Payment Out Plan"
.
No tags attached.
related to defect 00209553.0MP14 closed mtaal Is impossible to add a selector field in pick/execute windows 
Issue History
2012-07-27 10:32mtaalNew Issue
2012-07-27 10:32mtaalAssigned To => mtaal
2012-07-27 10:32mtaalModules => Core
2012-07-27 16:33mtaalSummaryPick & Execute Windows:Change reference of sales order line and m_inout_id to search to prevent FIC from assuming it is a combo => Pick & Execute Windows:Change reference of read only fields to not do combo value computation by FIC
2012-07-27 16:33mtaalDescription Updatedbug_revision_view_page.php?rev_id=3671#r3671
2012-07-27 16:53mtaalRelationship addedrelated to 0020955
2012-07-27 16:54hgbotCheckin
2012-07-27 16:54hgbotNote Added: 0050954
2012-07-27 16:54hgbotStatusnew => resolved
2012-07-27 16:54hgbotResolutionopen => fixed
2012-07-27 16:54hgbotFixed in SCM revision => http://code.openbravo.com/erp/devel/pi/rev/7f16a6a46998e2d1fdfe35f600283fa84506edf6 [^]
2012-07-28 01:24hudsonbotCheckin
2012-07-28 01:24hudsonbotNote Added: 0050967
2012-08-01 11:00marvintmStatusresolved => closed
2012-08-01 11:00marvintmFixed in Version => 3.0MP14

Notes
(0050954)
hgbot   
2012-07-27 16:54   
Repository: erp/devel/pi
Changeset: 7f16a6a46998e2d1fdfe35f600283fa84506edf6
Author: Martin Taal <martin.taal <at> openbravo.com>
Date: Fri Jul 27 16:53:37 2012 +0200
URL: http://code.openbravo.com/erp/devel/pi/rev/7f16a6a46998e2d1fdfe35f600283fa84506edf6 [^]

Fixes issue 21230: Pick & Execute Windows:Change reference of read only fields to not do combo value computation by FIC
Changed the reference of the storage bin to a selector and of several other columns to search: m_inout_id column, order line column

---
M src-db/database/sourcedata/AD_COLUMN.xml
---
(0050967)
hudsonbot   
2012-07-28 01:24   
A changeset related to this issue has been promoted main and to the
Central Repository, after passing a series of tests.

Promotion changeset: https://code.openbravo.com/erp/devel/main/rev/c6491bd9e10b [^]

Maturity status: Test