Project:
View Issue Details[ Jump to Notes ] | [ Issue History ] [ Print ] | |||||||
ID | ||||||||
0042491 | ||||||||
Type | Category | Severity | Reproducibility | Date Submitted | Last Update | |||
defect | [Retail Modules] Web POS | major | always | 2019-12-09 13:41 | 2019-12-16 13:03 | |||
Reporter | JONHM | View Status | public | |||||
Assigned To | ranjith_qualiantech_com | |||||||
Priority | high | Resolution | fixed | Fixed in Version | RR20Q1 | |||
Status | closed | Fix in branch | Fixed in SCM revision | 79b1435cc6e9 | ||||
Projection | none | ETA | none | Target Version | ||||
OS | Any | Database | Any | Java version | ||||
OS Version | Database version | Ant version | ||||||
Product Version | SCM revision | |||||||
Merge Request Status | ||||||||
Review Assigned To | jorge-garcia | |||||||
OBNetwork customer | Gold | |||||||
Support ticket | ||||||||
Regression level | ||||||||
Regression date | ||||||||
Regression introduced in release | ||||||||
Regression introduced by commit | ||||||||
Triggers an Emergency Pack | No | |||||||
Summary | 0042491: RFID scanFocus is set as ON after incremental refresh, even if there is a popup opened | |||||||
Description | RFID scanFocus is set as ON after incremental refresh, even if there is a popup opened. If there is any popup shown on POS, RFID should be disabled. | |||||||
Steps To Reproduce | * Configure RFID in backend: - "Channel - Touchpoint" window: Set Hardware URL: http://localhost:8090/printer [^] - "Channel - Touchpoint Type" window: Turn ON the [Use RFID] flag Turn ON the [Use External Input] flag Set "Time to Incrementally Refresh Masterdata (in minutes)" to 2 Set "Time to Show Incremental Refresh Popup (in minutes)" to 1 * Start Hardware Manager * Start Web POS: Check if RFID is on - OB.UTIL.RfidController.get('isRFIDEnabled') should be TRUE Open a popup (Menu > Verified Return) - OB.UTIL.RfidController.get('isRFIDEnabled') should be FALSE Wait for the incremental refresh - After this point, the isRFIDEnabled variable should be set as FALSE, as there is one popup opened, but is set as TRUE instead. | |||||||
Tags | No tags attached. | |||||||
Attached Files | ||||||||
![]() |
|
![]() |
|
(0116321) hgbot (developer) 2019-12-16 07:40 |
Repository: erp/pmods/org.openbravo.retail.posterminal Changeset: 79b1435cc6e91ce9bb1096adb48739e200b11320 Author: Ranjith S R <ranjith <at> qualiantech.com> Date: Mon Dec 16 12:09:08 2019 +0530 URL: http://code.openbravo.com/erp/pmods/org.openbravo.retail.posterminal/rev/79b1435cc6e91ce9bb1096adb48739e200b11320 [^] Fixed issue 42491 : Scanning Focus should be updated when master data is reloaded * RFID should not be connect/disconnect directly. It should be done via scanningFocus --- M web/org.openbravo.retail.posterminal/js/utils/ob-utilitiesuipos.js --- |
(0116343) jorge-garcia (viewer) 2019-12-16 13:03 |
Code reviewed and tested |
![]() |
|||
Date Modified | Username | Field | Change |
2019-12-09 13:41 | JONHM | New Issue | |
2019-12-09 13:41 | JONHM | Assigned To | => Retail |
2019-12-09 13:41 | JONHM | OBNetwork customer | => Gold |
2019-12-09 13:41 | JONHM | Resolution time | => 1577055600 |
2019-12-09 13:41 | JONHM | Triggers an Emergency Pack | => No |
2019-12-11 15:28 | ranjith_qualiantech_com | Assigned To | Retail => ranjith_qualiantech_com |
2019-12-12 08:16 | ranjith_qualiantech_com | Status | new => scheduled |
2019-12-16 07:40 | hgbot | Checkin | |
2019-12-16 07:40 | hgbot | Note Added: 0116321 | |
2019-12-16 07:40 | hgbot | Status | scheduled => resolved |
2019-12-16 07:40 | hgbot | Resolution | open => fixed |
2019-12-16 07:40 | hgbot | Fixed in SCM revision | => http://code.openbravo.com/erp/pmods/org.openbravo.retail.posterminal/rev/79b1435cc6e91ce9bb1096adb48739e200b11320 [^] |
2019-12-16 13:03 | jorge-garcia | Review Assigned To | => jorge-garcia |
2019-12-16 13:03 | jorge-garcia | Note Added: 0116343 | |
2019-12-16 13:03 | jorge-garcia | Status | resolved => closed |
2019-12-16 13:03 | jorge-garcia | Fixed in Version | => RR20Q1 |
Copyright © 2000 - 2009 MantisBT Group |