Project:
| View Issue Details[ Jump to Notes ] | [ Issue History ] [ Print ] | |||||||||||
| ID | ||||||||||||
| 0038432 | ||||||||||||
| Type | Category | Severity | Reproducibility | Date Submitted | Last Update | |||||||
| defect | [Modules] Advanced Warehouse Operations | major | always | 2018-04-23 19:31 | 2018-04-23 20:00 | |||||||
| Reporter | maarten1962 | View Status | public | |||||||||
| Assigned To | dmiguelez | |||||||||||
| Priority | urgent | Resolution | open | Fixed in Version | ||||||||
| Status | new | Fix in branch | Fixed in SCM revision | |||||||||
| Projection | none | ETA | none | Target Version | ||||||||
| OS | Any | Database | Any | Java version | ||||||||
| OS Version | Database version | Ant version | ||||||||||
| Product Version | SCM revision | |||||||||||
| Merge Request Status | ||||||||||||
| Regression date | ||||||||||||
| Regression introduced by commit | ||||||||||||
| Regression level | ||||||||||||
| Review Assigned To | ||||||||||||
| Support ticket | ||||||||||||
| OBNetwork customer | No | |||||||||||
| Regression introduced in release | ||||||||||||
| Summary | 0038432: Bin-Capacity should be defined with 2 decimals | |||||||||||
| Description | Currently the Bin-Capacity does not accpet any decimals. This is wrong because many bins do not have a full 1 (or multiple) Pallet capacity. Specially pick-face bins typically have separations to make from a 1 PL space, 2, 3 or somtimes 4 layers. See image. So it should be possible to define capacity as 0,25 - 0,50 - 0,75 - 1,50 PL. This should not be linked to the Standard Precision of the UOM because this is used in the Front-End to allow/disallow movements of units/pallets/... with decimals. | |||||||||||
| Steps To Reproduce | . | |||||||||||
| Proposed Solution | So it should be possible to define capacity as 0,25 - 0,50 - 0,75 - 1,50 PL. This should not be linked to the Standard Precision of the UOM because this is used in the Front-End to allow/disallow movements of units/pallets/... with decimals. | |||||||||||
| Tags | No tags attached. | |||||||||||
| Attached Files | ||||||||||||
Relationships [ Relation Graph ]
[ Dependency Graph ]
|
|
Notes |
|
|
(0104042) maarten1962 (viewer) 2018-04-23 20:00 |
The column is defined as DECIMAL in the DB, but has reference to INTEGER in the AD. Just change the AD (and recompile) should be suficient. |
Issue History |
|||
| Date Modified | Username | Field | Change |
| 2018-04-23 19:31 | maarten1962 | New Issue | |
| 2018-04-23 19:31 | maarten1962 | Assigned To | => dmiguelez |
| 2018-04-23 19:31 | maarten1962 | File Added: 2018-04-23 19_21_49-Bin-Cap no Decimals.png | |
| 2018-04-23 19:31 | maarten1962 | OBNetwork customer | => No |
| 2018-04-23 20:00 | maarten1962 | Note Added: 0104042 | |
| 2022-09-06 17:18 | caristu | Category | Advance Warehouse Operations => Advanced Warehouse Operations |