Anonymous | Login
Project:
RSS
  
News | My View | View Issues | Roadmap | Summary

View Issue DetailsJump to Notes ] Issue History ] Print ]
ID
0037337
TypeCategorySeverityReproducibilityDate SubmittedLast Update
defect[Retail Modules] Web POSmajoralways2017-11-21 09:052017-11-30 17:09
ReporterjorgewederagoView Statuspublic 
Assigned Toranjith_qualiantech_com 
PriorityurgentResolutionfixedFixed in VersionRR18Q1
StatusclosedFix in branchFixed in SCM revision104c2f6bc9b7
ProjectionnoneETAnoneTarget Version
OSAnyDatabaseAnyJava version
OS VersionDatabase versionAnt version
Product VersionSCM revision 
Review Assigned Tomarvintm
Regression level
Regression date
Regression introduced in release
Regression introduced by commit
Triggers an Emergency PackNo
Summary

0037337: RFID goes on even if a popup is open

DescriptionIf you have a popup opened and you keep it open enough time, the RFID will be switched to on automatically at some point.
It should maintain the previous state even if the socket gets closed.
Steps To Reproduce*Set up a HWM with RFID.
*Configure Use RFID in POS Terminal Type Window
*Remove RFID Timeout.
*Open HWM
*Login on WebPOS
*Open a popup (receipt properties for example) and check that the RFID is switched off.
*Wait for around 15 minutes.
*After certain time, the RFID button will automatically switched on.
Proposed SolutionSee diff attached
TagsNo tags attached.
Attached Filesdiff file icon issueRFID.diff [^] (1,231 bytes) 2017-11-21 09:20 [Show Content]

- Relationships Relation Graph ] Dependency Graph ]

-  Notes
(0100662)
hgbot (developer)
2017-11-22 10:49

Repository: erp/pmods/org.openbravo.retail.posterminal
Changeset: 104c2f6bc9b7432e797037db87e55b6166719406
Author: Ranjith S R <ranjith <at> qualiantech.com>
Date: Wed Nov 22 15:15:58 2017 +0530
URL: http://code.openbravo.com/erp/pmods/org.openbravo.retail.posterminal/rev/104c2f6bc9b7432e797037db87e55b6166719406 [^]

Fixed issue 37337 : Reset RFID status with Previoud after reconnection timeout

---
M web/org.openbravo.retail.posterminal/js/utils/rfidWebsocket.js
---

- Issue History
Date Modified Username Field Change
2017-11-21 09:05 jorgewederago New Issue
2017-11-21 09:05 jorgewederago Assigned To => Retail
2017-11-21 09:05 jorgewederago Resolution time => 1513033200
2017-11-21 09:05 jorgewederago Triggers an Emergency Pack => No
2017-11-21 09:10 guillermogil Description Updated View Revisions
2017-11-21 09:10 guillermogil Steps to Reproduce Updated View Revisions
2017-11-21 09:18 guillermogil Steps to Reproduce Updated View Revisions
2017-11-21 09:19 guillermogil Proposed Solution updated
2017-11-21 09:20 guillermogil File Added: issueRFID.diff
2017-11-21 10:33 ranjith_qualiantech_com Assigned To Retail => ranjith_qualiantech_com
2017-11-21 10:33 ranjith_qualiantech_com Status new => scheduled
2017-11-22 10:49 hgbot Checkin
2017-11-22 10:49 hgbot Note Added: 0100662
2017-11-22 10:49 hgbot Status scheduled => resolved
2017-11-22 10:49 hgbot Resolution open => fixed
2017-11-22 10:49 hgbot Fixed in SCM revision => http://code.openbravo.com/erp/pmods/org.openbravo.retail.posterminal/rev/104c2f6bc9b7432e797037db87e55b6166719406 [^]
2017-11-30 17:09 marvintm Review Assigned To => marvintm
2017-11-30 17:09 marvintm Status resolved => closed
2017-11-30 17:09 marvintm Fixed in Version => RR18Q1