Anonymous | Login
Project:
RSS
  
News | My View | View Issues | Roadmap | Summary

View Issue DetailsJump to Notes ] Issue History ] Print ]
ID
0010272
TypeCategorySeverityReproducibilityDate SubmittedLast Update
defect[Openbravo ERP] 00. Application dictionaryminoralways2009-08-14 05:272009-08-21 00:00
ReportereintelauView Statuspublic 
Assigned Torafaroda 
PrioritynormalResolutionfixedFixed in Version
StatusclosedFix in branchFixed in SCM revision88460deb3db2
ProjectionnoneETAnoneTarget Version
OSLinux 32 bitDatabasePostgreSQLJava version1.6
OS Version5.2Database version8.3Ant version1.7
Product VersionpiSCM revision4492:b10bedd14f64 
Review Assigned To
Web browser
ModulesCore
Regression level
Regression date
Regression introduced in release
Regression introduced by commit
Triggers an Emergency PackNo
Summary

0010272: Synchronize Terminology fails when module has process parameter without application element

DescriptionIf a module defines a process parameter, marks it as centrally maintained but does not specify a application element, then the Synchronize Terminology process will always fail when that module is not in development.
Steps To Reproduce1) Create a module with a process and process parameter
2) Set the process parameter as centrally maintained
3) Set the application element to empty
4) Deploy the module & take it out of development
5) Put any other module into development
6) Run synchronise terminology
7) Fails with "Cannot update an object in a module not in developement and without an active template"
Proposed SolutionAdd check in the AD_SYNCHRONISE process when changing status of process parameters to be not centrally maintained to only change process parameters that belong to a module currently in development
TagsNo tags attached.
Attached Files

- Relationships Relation Graph ] Dependency Graph ]

-  Notes
(0018940)
hgbot (developer)
2009-08-14 05:30

Repository: erp/devel/pi
Changeset: 88460deb3db291935ec656a29faf8af0c681aaa9
Author: Ben Sommerville <ben.sommerville <at> eintel.com.au>
Date: Fri Aug 14 13:28:44 2009 +1000
URL: http://code.openbravo.com/erp/devel/pi/rev/88460deb3db291935ec656a29faf8af0c681aaa9 [^]

Fixes issue 0010272: AD_SYNCHRONIZE doesn't check if AD_PROCESS_PARA is in development when updating CentrallyMaintained status

---
M src-db/database/model/functions/AD_SYNCHRONIZE.xml
---

- Issue History
Date Modified Username Field Change
2009-08-14 05:27 eintelau New Issue
2009-08-14 05:27 eintelau Assigned To => rafaroda
2009-08-14 05:30 hgbot Checkin
2009-08-14 05:30 hgbot Note Added: 0018940
2009-08-14 05:30 hgbot Status new => resolved
2009-08-14 05:30 hgbot Resolution open => fixed
2009-08-14 05:30 hgbot Fixed in SCM revision => http://code.openbravo.com/erp/devel/pi/rev/88460deb3db291935ec656a29faf8af0c681aaa9 [^]
2009-08-20 13:09 plujan Status resolved => closed
2009-08-21 00:00 anonymous sf_bug_id 0 => 2841464


Copyright © 2000 - 2009 MantisBT Group
Powered by Mantis Bugtracker