Anonymous | Login
Project:
RSS
  
News | My View | View Issues | Roadmap | Summary

View Issue DetailsJump to Notes ] Issue History ] Print ]
ID
0055064
TypeCategorySeverityReproducibilityDate SubmittedLast Update
defect[POS2] POSmajoralways2024-03-27 09:202024-04-24 17:39
ReporterLeyreView Statuspublic 
Assigned Toranjith_qualiantech_com 
PriorityhighResolutionfixedFixed in Version24Q3
StatusclosedFix in branchFixed in SCM revision
ProjectionnoneETAnoneTarget Version
OSAnyDatabaseAnyJava version
OS VersionDatabase versionAnt version
Product VersionSCM revision 
Review Assigned To
Regression level
Regression date
Regression introduced in release
Regression introduced by commit
Triggers an Emergency PackNo
Summary

0055064: POS2 - Loss of focus when scanning a code

DescriptionPOS2 - Loss of focus when scanning a code
Steps To Reproduce1. Open a POS 2 terminal.
2. Open the "Sell" window
3. Put the focus on the "Code" field.
4. Add an invalid code, for example: 123
5. A new pop-up is opened: "The code '123' cannot be found"
6. Click "Ok"
Result: Focus is lost and the cashier has to click again on the "Code" field.

Note: If the steps are:
1. Open a web POS 2 terminal.
2. Open the "Sell" window
3. Put the focus on the "Code" field.
4. Change to other view, for example "Orders"
5. Return to the "Sell window"
Result: The focus is correctly on the "Code" field. It is not lost.

Video: https://youtu.be/tMVcqcsa8D4 [^]
TagsNo tags attached.
Attached Files

- Relationships Relation Graph ] Dependency Graph ]

-  Notes
(0162798)
hgbot (developer)
2024-04-03 09:30

Merge Request created: https://gitlab.com/openbravo/product/pmods/org.openbravo.pos2/-/merge_requests/2539 [^]
(0163677)
hgbot (developer)
2024-04-24 17:39

Directly closing issue as related merge request is already approved.

Repository: https://gitlab.com/openbravo/product/pmods/org.openbravo.pos2 [^]
Changeset: bb28827752aa676efbbe476e40afcea9e00c3e39
Author: Ranjith S R <ranjith.rangaraju.ext@openbravo.com>
Date: 24-04-2024 15:36:53
URL: https://gitlab.com/openbravo/product/pmods/org.openbravo.pos2/-/commit/bb28827752aa676efbbe476e40afcea9e00c3e39 [^]

Fixed ISSUE-55064: Product Scan keypad should get focus after notification closed

---
M web-jspack/org.openbravo.pos2/src/components/ProductScan/ProductScan.jsx
---
(0163678)
hgbot (developer)
2024-04-24 17:39

Merge request merged: https://gitlab.com/openbravo/product/pmods/org.openbravo.pos2/-/merge_requests/2539 [^]

- Issue History
Date Modified Username Field Change
2024-03-27 09:20 Leyre New Issue
2024-03-27 09:20 Leyre Assigned To => Retail
2024-03-27 09:20 Leyre Triggers an Emergency Pack => No
2024-03-27 09:49 Practics Issue Monitored: Practics
2024-04-02 11:12 marvintm Status new => acknowledged
2024-04-02 11:13 ranjith_qualiantech_com Assigned To Retail => ranjith_qualiantech_com
2024-04-02 11:13 ranjith_qualiantech_com Status acknowledged => scheduled
2024-04-03 09:30 hgbot Note Added: 0162798
2024-04-24 17:39 hgbot Resolution open => fixed
2024-04-24 17:39 hgbot Status scheduled => closed
2024-04-24 17:39 hgbot Fixed in Version => 24Q3
2024-04-24 17:39 hgbot Note Added: 0163677
2024-04-24 17:39 hgbot Note Added: 0163678


Copyright © 2000 - 2009 MantisBT Group