Anonymous | Login
Project:
RSS
  
News | My View | View Issues | Roadmap | Summary

View Issue DetailsJump to Notes ] Issue History ] Print ]
ID
0029083
TypeCategorySeverityReproducibilityDate SubmittedLast Update
design defect[Openbravo ERP] A. Platformminoralways2015-02-26 17:382022-02-01 08:09
ReportercaristuView Statuspublic 
Assigned ToTriage Platform Base 
PrioritynormalResolutionopenFixed in Version
StatusacknowledgedFix in branchFixed in SCM revision
ProjectionnoneETAnoneTarget Version
OSAnyDatabaseAnyJava version
OS VersionDatabase versionAnt version
Product VersionpiSCM revision 
Review Assigned To
Web browser
ModulesCore
Regression level
Regression date
Regression introduced in release
Regression introduced by commit
Triggers an Emergency PackNo
Summary

0029083: Is not possible to use the Location selector in the parameter windows of Process Definition

DescriptionIs not possible to use the Location selector in the parameter windows of Process Definition
Steps To Reproduce1) Create a new standard process in the [Process Definition] window
2) Assign a parameter with reference "Search" and Reference Search Key "Location"
3) Execute the new process, the parameter window will appear. Click on the magnifying glass button of the Location selector. The pop-up is not opened. The following error is raised in the console: "Uncaught TypeError: Cannot read property 'standardWindow' of undefined"
TagsNo tags attached.
Attached Files

- Relationships Relation Graph ] Dependency Graph ]
related to defect 00286203.0PR15Q3 closedinigosanchez Button reference is not displayed properly in parameter windows 
related to feature request 0029309 newdbaz Add the posibility to change the size of the Location selector when customizing it. 

-  Notes
(0075229)
alostale (manager)
2015-03-06 09:27

Location selector has two peculiarities:

1. It is a 2.50 only style component
2. It is used to create new locations not to select exiting ones

Supporting 2.50 components in new process definition is not currently in the plan.

What is the functional goal of adding this component (which creates new locations) as a parameter?

The plan is simply removing it as an option to be selected as reference for a parameter in process definition.
(0088609)
egoitz (developer)
2016-07-21 10:24

The limiations section of the wiki should be udpated:
http://wiki.openbravo.com/wiki/How_to_create_a_Standard_Process_Definition#Limitations [^]
(0088611)
caristu (developer)
2016-07-21 11:06

Updated: http://wiki.openbravo.com/wiki/How_to_create_a_Standard_Process_Definition#Limitations [^]

- Issue History
Date Modified Username Field Change
2015-02-26 17:38 caristu New Issue
2015-02-26 17:38 caristu Assigned To => AugustoMauch
2015-02-26 17:38 caristu Modules => Core
2015-02-26 17:38 caristu Resolution time => 1427666400
2015-02-26 17:38 caristu Triggers an Emergency Pack => No
2015-02-26 17:38 caristu Issue Monitored: networkb
2015-02-27 09:19 heccam Issue Monitored: heccam
2015-03-06 09:00 alostale Relationship added related to 0028620
2015-03-06 09:27 alostale Note Added: 0075229
2015-03-06 09:28 alostale Status new => acknowledged
2015-03-11 08:02 alostale Note View State: public: 75229
2015-03-16 13:27 jonalegriaesarte Resolution time 1427666400 =>
2015-03-17 09:59 egoitz Relationship added related to 0029309
2015-03-17 14:37 alostale Assigned To AugustoMauch => platform
2015-03-25 09:04 alostale Target Version 3.0PR15Q2 =>
2015-11-11 11:37 alostale Priority urgent => normal
2016-07-21 10:24 egoitz Note Added: 0088609
2016-07-21 11:06 caristu Note Added: 0088611
2016-12-01 14:40 alostale Type defect => design defect
2022-02-01 08:09 alostale Assigned To platform => Triage Platform Base