View Revisions: Issue #37372 All Revisions ] Back to Issue ]
Summary 0037372: When switching languages in WebPOS if you have something in the RFID you will get an error with it's stacktrace.
Revision 2017-12-01 07:34 by guillermogil
Steps To Reproduce *Set up a HWM with RFID.
*Configure Use RFID in POS Terminal Type Window
*Remove RFID Timeout.
*Open HWM
*Log in WebPOS
*Change languages.
*On the loading screen you will see that RFID is activated during 1 second.
If a product gets added at that timer the error and stacktrace will appear
Revision 2017-11-23 09:28 by jorgewederago
Steps To Reproduce *Set up a HWM with RFID.
*Configure Use RFID in POS Terminal Type Window
*Set up SCO
*Remove RFID Timeout.
*Open HWM
*Log in SCO
*Change languages.
*On the loading screen add a new product using RFID
*The error and stacktrace will appear
Revision 2017-11-23 09:24 by jorgewederago
Steps To Reproduce *Set up a hardware manager with RFID in screen mode
*Set up SCO
*Once in SCO try to chang languages.
*On the loading screen add a new product using RFID
*The error and stacktrace will appear