Anonymous | Login
Project:
RSS
  
News | My View | View Issues | Roadmap | Summary

View Revisions: Issue #37842 Back to Issue ]
Summary 0037842: Callout not triggered when clearing a selector
Revision 2018-02-14 13:31 by AugustoMauch
Steps To Reproduce Open the Sales Invoice window
- Create a record in the header tab
- In the Lines tab, select a product. Check that the price is updated
- Now give an empty value to the product field. Check that the price is not being emptied (this would have been done had the callout been called)
Revision 2018-02-14 09:41 by AugustoMauch
Steps To Reproduce Associate a callout with a nullable column with a OBUISEL_Selector Reference.
Compile and restart tomcat in debug mode.
Set a break point at the beginning of the callout.
Create a new record in the correspondent window. Select any value in the selector and change the focus. Verify the callout is properly triggered. OK
Now clears the selector and change the focus. The callout is NOT triggered. WRONG.


Copyright © 2000 - 2009 MantisBT Group