Revision | 2014-10-23 10:46 by VictorVillar | ||
Steps To Reproduce | As group Admin role, Navigate to Product window: Check Production = YES for Cerverza Ale Cerveza Lager Vino Blanco For Cerveza Ale go to Manufacturing Tab: create a new register: Organization España Storage Bin: RN-0-0-0 create a new register: Organization España Región Norte Storage Bin: RN-2-0-0 Cerveza Lager and Vino Blanco should not have any register in the Manufacturing tab. Go to Physical Inventory window, create a new register and empty the units from RN 0-0-0 for Vino Blanco and for Cerveza lager. There should not be any stock of these products in that bin. Go to Activity window: Create a new register, name: Actividad Go to Process Plan window: Organization: * Name: Test Version tab: Starting Date: 01-01-2014 Ending Date: 31-10-9999 Operation tab: Name: sec Activity: Actividad I/O Products tab New register: P+ Cerveza Ale, Qty: 1 New register: P- Cerveza Lager Qty: 1 New register: P- Vino Blanco Qty: 1 Go to Work Requirement window, Starting Date: Today Ending Date: today Process Plan: Test Organization: España Región Norte Qty: 1 Click on Process Work Requirement button Realise that the Operation and Products have been populated with the Process Plan data Go to Work Effort window: Organization: España Región Norte Starting time: 2 Ending Time: 3 Go to Production Run tab: Select the Work Requirement Phase created before Completed Qty: 1 Click on Create Standards button The following error appears: null value in column "m_locator_id" violates not-null constraint |
||
Revision | 2014-10-23 10:40 by VictorVillar | ||
Steps To Reproduce | As group Admin role, Navigate to Product window: Check Production = YES for Cerverza Ale Cerveza Lager Vino Blanco For Cerveza Ale go to Manufacturing Tab: create a new register: Organization España Storage Bin: RN-0-0-0 create a new register: Organization España Región Norte Storage Bin: RN-2-0-0 Cerveza Lager and Vino Blanco should not have any register in the Manufacturing tab. Go to Physical Inventory window, create a new register and empty the units from RN 0-0-0 for Vino Blanco and for Cerveza lager. There should not be any stock of these products in that bin. Go to Activity window: Create a new register, name: Actividad Go to Process Plan window: Organization: * Name: Test Version tab: Starting Date: 01-01-2014 Ending Date: 31-10-9999 Operation tab: Name: sec Activity: Actividad I/O Products tab New register: P+ Cerveza Ale, Qty: 1 New register: P- Cerveza Lager Qty: 1 New register: P- Vino Blanco Qty: 1 Go to Work Requirement window, Starting Date: Today Ending Date: today Process Plan: Test Organization: España Región Norte Qty: 1 Click on Process Work Requirement button Realise that the Operation and Products have been populated with the Process Plan data Go to Work Effort window: Organization: España Starting time: 2 Ending Time: 3 Go to Production Run tab: Select the Work Requirement Phase created before Completed Qty: 1 Click on Create Standards button The following error appears: null value in column "m_locator_id" violates not-null constraint |
||
Revision | 2014-10-17 08:39 by VictorVillar | ||
Steps To Reproduce | As group Admin role, Navigate to Product window: Check Production = YES for Cerverza Ale Cerveza Lager Vino Blanco For Cerveza Ale go to Manufacturing Tab: create a new register: Organization España Storage Bin: RN-0-0-0 Cerveza Lager and Vino Blanco should not have any register in the Manufacturing tab. Go to Activity window: Creata a new register, name: Actividad Go to Process Plan window: Organization: * Name: Test Version tab: Starting Date: 01-01-2014 Ending Date: 31-10-9999 Operation tab: Name: sec Activity: Actividad I/O Products tab New register: P+ Cerveza Ale, Qty: 1 New register: P- Cerveza Lager Qty: 1 New register: P- Vino Blanco Qty: 1 Go to Work Requirement window, Starting Date: Today Ending Date: today Process Plan: Test Organization: España Qty: 1 Click on Process Work Requirement button Realise that the Operation and Products have been populated with the Process Plan data Go to Work Effort window: Organization: España Starting time: 1 Ending Time: 2 Go to Production Run tab: Select the Work Requirement Phase created before Completed Qty: 1 Click on Create Standards button The following error appears: null value in column "m_locator_id" violates not-null constraint |
||
Revision | 2014-10-14 17:36 by VictorVillar | ||
Steps To Reproduce | Create a work effort for a work requirement that contains raw materials (P-), at least two, without a storage bin defined in the Manufacturing tab (Product window). The produced products (P+) should have defined the storage bin in the Manufacturing tab. In window Work Effort create standards for a Production Run. The following error appears: null value in column "m_locator_id" violates not-null constraint |
||
Revision | 2014-08-28 07:53 by VictorVillar | ||
Description | The error message should be different for not having the Storage Bin defined, after executing the Create Standards | ||
Revision | 2014-08-28 07:50 by VictorVillar | ||
Description | The error message for not having the Storage Bin defined in Create Standards should be different |