Openbravo Issue Tracking System - POS2
View Issue Details
0057896POS2POSpublic2025-02-06 16:102025-02-07 10:55
asier_perez 
Triage Platform Conn 
normalmajoralways
closedunable to reproduce 
5
pi 
 
QA functional test
main
No
0057896: [25Q1] Products are added twice to the order when scanned with a Zebra ET40 device
When using the scanner of a Zebra ET40 device to scan a bar code, the product is added with quantity 2 to the order.

The issue is reproducible from 25Q1 onwards.
1) Configure a product to have a valid UPC/EAN that you can scan with the Zebra ET40 device
2) In the device, log in to POS
3) Scan the bar code => The product is added twice to the order
No tags attached.
Issue History
2025-02-06 16:10asier_perezNew Issue
2025-02-06 16:10asier_perezAssigned To => Retail
2025-02-06 16:10asier_perezTriggers an Emergency Pack => No
2025-02-06 16:22asier_perezRegression level => QA functional test
2025-02-06 16:22asier_perezversion => pi
2025-02-06 16:22asier_perezDescription Updatedbug_revision_view_page.php?rev_id=29219#r29219
2025-02-06 16:25asier_perezDescription Updatedbug_revision_view_page.php?rev_id=29220#r29220
2025-02-06 16:29aaroncaleroAssigned ToRetail => Triage Platform Conn
2025-02-06 17:28martinsdanIssue Monitored: martinsdan
2025-02-07 09:48lorenzofidalgoRegression introduced in release => main
2025-02-07 10:55asier_perezNote Added: 0175280
2025-02-07 10:55asier_perezStatusnew => closed
2025-02-07 10:55asier_perezResolutionopen => unable to reproduce

Notes
(0175280)
asier_perez   
2025-02-07 10:55   
It is not an issue, since the products were configured with a sales factor unit of 2.