Openbravo Issue Tracking System - Openbravo ERP
View Issue Details
0050464Openbravo ERP04. Warehouse managementpublic2022-10-10 11:132023-03-02 09:39
XABIER_AGUADO 
ranjith_qualiantech_com 
highmajoralways
closedunable to reproduce 
5
 
 
migueldejuana
Core
No
0050464: [AWO PDA] The PDA zooms out when we scan a product
When we try scanning a product, the PDA screen zooms out and becomes completely unreadable.
Video: https://drive.google.com/file/d/1QNAzkNTeL8_2tD95ZB7T5o3BFqCsshQ0/view [^]
Put rotation on PDA

Click on an input field to display the keyboard

Rotate the PDA
When scanning a product, nothing should happen to the screen
FASH
png Screenshot_27.png (383,756) 2022-10-10 11:13
https://issues.openbravo.com/file_download.php?file_id=17599&type=bug
diff 50464_pi_mobilecore.diff (1,449) 2023-01-30 09:55
https://issues.openbravo.com/file_download.php?file_id=18077&type=bug
Issue History
2022-10-10 11:13XABIER_AGUADONew Issue
2022-10-10 11:13XABIER_AGUADOAssigned To => Triage Omni WMS
2022-10-10 11:13XABIER_AGUADOFile Added: Screenshot_27.png
2022-10-10 11:13XABIER_AGUADOModules => Core
2022-10-10 11:13XABIER_AGUADOTriggers an Emergency Pack => No
2022-10-10 11:16XABIER_AGUADOTag Attached: FASH
2022-10-17 18:08vmromanosAssigned ToTriage Omni WMS => migueldejuana
2022-11-04 13:20migueldejuanaAssigned Tomigueldejuana => Triage Omni WMS
2022-11-24 16:49migueldejuanaNote Added: 0144120
2022-12-15 11:23vmromanosAssigned ToTriage Omni WMS => Retail
2023-01-23 11:09ranjith_qualiantech_comAssigned ToRetail => ranjith_qualiantech_com
2023-01-23 11:09ranjith_qualiantech_comStatusnew => scheduled
2023-01-30 09:55ranjith_qualiantech_comFile Added: 50464_pi_mobilecore.diff
2023-03-02 09:39migueldejuanaReview Assigned To => migueldejuana
2023-03-02 09:39migueldejuanaNote Added: 0147215
2023-03-02 09:39migueldejuanaStatusscheduled => closed
2023-03-02 09:39migueldejuanaResolutionopen => unable to reproduce

Notes
(0144120)
migueldejuana   
2022-11-24 16:49   
It only happens when a popup is opened and the virtual keyboard is shown(we have the focus in an input).
It is related with the resize of the window, check resizeWindow function in 'OB.UI.Terminal' component.
We should save last portrait sizes or check if virtual keyboard is shown.
(0147215)
migueldejuana   
2023-03-02 09:39   
No longer reproducible.

Tested in https://livebuilds.openbravo.com/ [^] with two devices:
- Zebra tc21, Android 10, Chrome version is 109.0.5414.85 in Pamplona office
- Zebra tc26, Android 11, Chrome version is 109.0.5414.118 in Lille office.