0039654ModulesAdvanced Warehouse Operationspublic2018-11-20 12:262018-11-20 12:28
RenateNieuwkoop 
Triage Omni WMS 
normalminoralways
newopen 
5
 
 
0039654: AWO: the Warehouse Configuration Check gives an error concerning process requests not set up
When running the Warehouse Configuration Check there is always an error that the process requests for Increment Task priority, Reprocess Error Import Errors and Recalculate Storage Bin Occupancy are not set up at the organization level nor at a parent level.

However, as part of the sample data, this is set up at the client F&B International Group for Organization *

See screenshots
Run the Warehouse Configuration Check process in AWO for Organization F&B US, Inc. and leave the warehouse blank - scroll to almost the bottom in the results to see the 3 errors
That the check takes the parent - children structure into account correctly.
No tags attached.
png AWOprocesserror1.png (92,978) 2018-11-20 12:26
https://issues.openbravo.com/file_download.php?file_id=12370&type=bug
png

png AWOprocesserror2.png (69,930) 2018-11-20 12:27
https://issues.openbravo.com/file_download.php?file_id=12371&type=bug
png

png AWOprocesserror3.png (51,665) 2018-11-20 12:27
https://issues.openbravo.com/file_download.php?file_id=12372&type=bug
png

png AWOprocesserror4.png (73,876) 2018-11-20 12:28
https://issues.openbravo.com/file_download.php?file_id=12373&type=bug
png
Issue History
2018-11-20 12:26RenateNieuwkoopNew Issue
2018-11-20 12:26RenateNieuwkoopAssigned To => Triage Finance
2018-11-20 12:26RenateNieuwkoopFile Added: AWOprocesserror1.png
2018-11-20 12:27RenateNieuwkoopFile Added: AWOprocesserror2.png
2018-11-20 12:27RenateNieuwkoopFile Added: AWOprocesserror3.png
2018-11-20 12:28RenateNieuwkoopFile Added: AWOprocesserror4.png
2022-09-06 17:18caristuCategoryAdvance Warehouse Operations => Advanced Warehouse Operations

There are no notes attached to this issue.