0035555: Check Drawer status does not work
Check Drawer status does not work with EPSON TM-T88IV and POSIFLEX CR6000.
HWM screen test seems to be working.

It is returning always an error and that creates a wrong behavior on WebPOS
With EPSON TM-T88IV and POSIFLEX CR6000
Configure HWM properties file
Open the HWM
Click Test Drawer
Click Check Drawer Status

You will see that Error is always returned
No tags attached.
blocks defect 0035550 closed jorge-garcia Check Drawer status does not work 
Issue History
2017-03-17 10:31jorge-garciaTypedefect => backport
2017-03-17 10:31jorge-garciaTarget Version => RR16Q4.3
2017-03-17 11:47hgbotCheckin
2017-03-17 11:47hgbotNote Added: 0095368
2017-03-17 11:47hgbotStatusscheduled => resolved
2017-03-17 11:47hgbotResolutionopen => fixed
2017-03-17 11:47hgbotFixed in SCM revision => http://code.openbravo.com/retail/backports/3.0RR16Q4.3/org.openbravo.retail.poshwmanager.sources/rev/780c9c8c111e0554b13bebf2e130e0c23318f361 [^]
2017-03-17 11:48hgbotCheckin
2017-03-17 11:48hgbotNote Added: 0095369
2017-03-23 11:07jorge-garciaAssigned ToRetail => jorge-garcia
2017-04-18 20:32guilleaerReview Assigned To => guilleaer
2017-04-18 20:32guilleaerStatusresolved => closed
2017-04-18 20:32guilleaerFixed in Version => RR16Q4.3

Notes
(0095368)
hgbot   
2017-03-17 11:47   
Repository: retail/backports/3.0RR16Q4.3/org.openbravo.retail.poshwmanager.sources
Changeset: 780c9c8c111e0554b13bebf2e130e0c23318f361
Author: Jorge Garcia <jorge.garcia <at> openbravo.com>
Date: Fri Mar 17 10:36:29 2017 +0100
URL: http://code.openbravo.com/retail/backports/3.0RR16Q4.3/org.openbravo.retail.poshwmanager.sources/rev/780c9c8c111e0554b13bebf2e130e0c23318f361 [^]

Fixed issue 35555: Check Drawer status does not work

Reverted code to manage properly the status of drawer.

---
M project/src/com/openbravo/pos/printer/escpos/DevicePrinterESCPOS.java
---
(0095369)
hgbot   
2017-03-17 11:48   
Repository: retail/backports/3.0RR16Q4.3/org.openbravo.retail.poshwmanager
Changeset: a2544fbd15b84a66be4a2a66a11b84e207cdb499
Author: Jorge Garcia <jorge.garcia <at> openbravo.com>
Date: Fri Mar 17 10:36:06 2017 +0100
URL: http://code.openbravo.com/retail/backports/3.0RR16Q4.3/org.openbravo.retail.poshwmanager/rev/a2544fbd15b84a66be4a2a66a11b84e207cdb499 [^]

Related to issue 35555: Check Drawer status does not work

Compile hwmanager

---
M bin/poshw.jar
M bin/rev.id
---