Openbravo Issue Tracking System - Retail Modules
View Issue Details
0035554Retail ModulesWeb POS Hardware Managerpublic2017-03-17 08:552017-04-27 12:31
guillermogil 
jorge-garcia 
immediatecriticalalways
closedfixed 
5
 
RR17Q1.1RR17Q1.1 
marvintm
Production - Confirmed Stable
2014-09-04
RR14Q4
https://code.openbravo.com/erp/pmods/org.openbravo.retail.poshwmanager.sources/rev/fc8956a468f3 [^]
No
0035554: Check Drawer status does not work
Check Drawer status does not work with EPSON TM-T88IV and POSIFLEX CR6000.
HWM screen test seems to be working.

It is returning always an error and that creates a wrong behavior on WebPOS
With EPSON TM-T88IV and POSIFLEX CR6000
Configure HWM properties file
Open the HWM
Click Test Drawer
Click Check Drawer Status

You will see that Error is always returned
No tags attached.
blocks defect 0035550 closed jorge-garcia Check Drawer status does not work 
Issue History
2017-03-17 10:31jorge-garciaTypedefect => backport
2017-03-17 10:31jorge-garciaTarget Version => RR17Q1.1
2017-03-17 11:45hgbotCheckin
2017-03-17 11:45hgbotNote Added: 0095366
2017-03-17 11:45hgbotStatusscheduled => resolved
2017-03-17 11:45hgbotResolutionopen => fixed
2017-03-17 11:45hgbotFixed in SCM revision => http://code.openbravo.com/retail/backports/3.0RR17Q1.1/org.openbravo.retail.poshwmanager.sources/rev/f431f8f67556fb04d3e368135cd2323b08a72725 [^]
2017-03-17 11:46hgbotCheckin
2017-03-17 11:46hgbotNote Added: 0095367
2017-03-23 11:07jorge-garciaAssigned ToRetail => jorge-garcia
2017-04-27 12:31marvintmReview Assigned To => marvintm
2017-04-27 12:31marvintmStatusresolved => closed
2017-04-27 12:31marvintmFixed in Version => RR17Q1.1

Notes
(0095366)
hgbot   
2017-03-17 11:45   
Repository: retail/backports/3.0RR17Q1.1/org.openbravo.retail.poshwmanager.sources
Changeset: f431f8f67556fb04d3e368135cd2323b08a72725
Author: Jorge Garcia <jorge.garcia <at> openbravo.com>
Date: Fri Mar 17 11:01:53 2017 +0100
URL: http://code.openbravo.com/retail/backports/3.0RR17Q1.1/org.openbravo.retail.poshwmanager.sources/rev/f431f8f67556fb04d3e368135cd2323b08a72725 [^]

Fixed issue 35554: Check Drawer status does not work

Reverted code to manage properly the status of drawer.

---
M project/src/com/openbravo/pos/printer/escpos/DevicePrinterESCPOS.java
---
(0095367)
hgbot   
2017-03-17 11:46   
Repository: retail/backports/3.0RR17Q1.1/org.openbravo.retail.poshwmanager
Changeset: 84c687e8b6a0da4d69f99c6e966504edb36717d4
Author: Jorge Garcia <jorge.garcia <at> openbravo.com>
Date: Fri Mar 17 11:03:29 2017 +0100
URL: http://code.openbravo.com/retail/backports/3.0RR17Q1.1/org.openbravo.retail.poshwmanager/rev/84c687e8b6a0da4d69f99c6e966504edb36717d4 [^]

Related to issue 35554: Check Drawer status does not work

Compile hwmanager

---
M bin/poshw.jar
M bin/rev.id
---