Openbravo Issue Tracking System - Retail Modules
View Issue Details
0035550Retail ModulesWeb POS Hardware Managerpublic2017-03-17 08:552017-03-24 11:02
guillermogil 
jorge-garcia 
immediatemajoralways
closedfixed 
5
 
RR17Q2 
marvintm
Production - Confirmed Stable
2014-09-04
RR14Q4
https://code.openbravo.com/erp/pmods/org.openbravo.retail.poshwmanager.sources/rev/fc8956a468f3 [^]
No
0035550: Check Drawer status does not work
Check Drawer status does not work with EPSON TM-T88IV and POSIFLEX CR6000.
HWM screen test seems to be working.

It is returning always an error and that creates a wrong behavior on WebPOS
With EPSON TM-T88IV and POSIFLEX CR6000
Configure HWM properties file
Open the HWM
Click Test Drawer
Click Check Drawer Status

You will see that Error is always returned
No tags attached.
related to defect 0035547 closed Retail Hardware manager does not open if you uses a virtualized port 
depends on backport 0035554RR17Q1.1 closed jorge-garcia Check Drawer status does not work 
depends on backport 0035555RR16Q4.3 closed jorge-garcia Check Drawer status does not work 
Issue History
2017-03-17 08:55guillermogilNew Issue
2017-03-17 08:55guillermogilAssigned To => Retail
2017-03-17 08:55guillermogilRegression level => Production - Confirmed Stable
2017-03-17 08:55guillermogilTriggers an Emergency Pack => No
2017-03-17 08:55guillermogilRelationship addedrelated to 0035547
2017-03-17 09:17guillermogilRegression introduced in release => RR14Q4
2017-03-17 09:57guillermogilRegression introduced by commit => https://code.openbravo.com/erp/pmods/org.openbravo.retail.poshwmanager.sources/rev/fc8956a468f3 [^]
2017-03-17 10:19jorge-garciaRegression date => 2014-09-04
2017-03-17 10:31jorge-garciaStatusnew => scheduled
2017-03-17 10:31jorge-garciaNote Added: 0095358
2017-03-17 10:31jorge-garciaAssigned ToRetail => jorge-garcia
2017-03-17 11:43hgbotCheckin
2017-03-17 11:43hgbotNote Added: 0095364
2017-03-17 11:43hgbotStatusscheduled => resolved
2017-03-17 11:43hgbotResolutionopen => fixed
2017-03-17 11:43hgbotFixed in SCM revision => http://code.openbravo.com/erp/pmods/org.openbravo.retail.poshwmanager.sources/rev/c60cc9f812b94170a46bb96d026416e644286bb2 [^]
2017-03-17 11:44hgbotCheckin
2017-03-17 11:44hgbotNote Added: 0095365
2017-03-20 13:07guillermogilResolution time => 1490565600
2017-03-24 11:02marvintmSeveritycritical => major
2017-03-24 11:02marvintmReview Assigned To => marvintm
2017-03-24 11:02marvintmStatusresolved => closed
2017-03-24 11:02marvintmFixed in Version => RR17Q2

Notes
(0095358)
jorge-garcia   
2017-03-17 10:31   
Changeset is not "linked" to an issue, caused by info can't be updated
(0095364)
hgbot   
2017-03-17 11:43   
Repository: erp/pmods/org.openbravo.retail.poshwmanager.sources
Changeset: c60cc9f812b94170a46bb96d026416e644286bb2
Author: Jorge Garcia <jorge.garcia <at> openbravo.com>
Date: Fri Mar 17 10:23:42 2017 +0100
URL: http://code.openbravo.com/erp/pmods/org.openbravo.retail.poshwmanager.sources/rev/c60cc9f812b94170a46bb96d026416e644286bb2 [^]

Fixed issue 35550: Check Drawer status does not work

Reverted code to manage properly the status of drawer.

---
M project/src/com/openbravo/pos/printer/escpos/DevicePrinterESCPOS.java
---
(0095365)
hgbot   
2017-03-17 11:44   
Repository: erp/pmods/org.openbravo.retail.poshwmanager
Changeset: 2ec9ffdf817c9b4b13f2724f9fa1ad2f29ca05fd
Author: Jorge Garcia <jorge.garcia <at> openbravo.com>
Date: Fri Mar 17 10:48:10 2017 +0100
URL: http://code.openbravo.com/erp/pmods/org.openbravo.retail.poshwmanager/rev/2ec9ffdf817c9b4b13f2724f9fa1ad2f29ca05fd [^]

Related to issue 35550: Check Drawer status does not work

Compile hwmanager

---
M bin/poshw.jar
M bin/rev.id
---