Openbravo Issue Tracking System - Openbravo ERP
View Issue Details
0020305Openbravo ERP00. Application dictionarypublic2012-04-18 17:502012-05-29 18:43
VictorVillar 
ioritzCia 
highminoralways
closedfixed 
5
3.0MP10.1 
3.0MP12 
Core
No
0020305: table MA_sequence_machine has not assigned a window
When the user creates a selector of the MA_sequence_machine table the link does not navigate to any window.
The problem is that in the Application Dictionary this table has not assigned any window.
As System admin role,
Create a reference and define a selector of the table MA_Sequence_Machine. http://wiki.openbravo.com/wiki/Selectors#Step_2:_Define_the_Selector [^]
Once you have assigned it with a column and with field. After compile and restart tomcat.
We realise that you cannot navigate if you try to click in the name link above the selector.
The problem is that this table MA_Sequence_Machine has not assigned any window.

To check it, naviagte to tables and columns window:
select MA_Sequence_Machine.
we can see that Window field is empty
it should be assigned Process Plan window.
No tags attached.
Issue History
2012-04-18 17:50VictorVillarNew Issue
2012-04-18 17:50VictorVillarAssigned To => alostale
2012-04-18 17:50VictorVillarModules => Core
2012-04-18 17:50VictorVillarResolution time => 1339365600
2012-04-18 17:50VictorVillarIssue Monitored: networkb
2012-04-19 08:43alostaleAssigned Toalostale => vmromanos
2012-04-19 17:40vmromanosAssigned Tovmromanos => jonalegriaesarte
2012-05-10 17:11ioritzCiaAssigned Tojonalegriaesarte => ioritzCia
2012-05-24 20:38ioritzCiaStatusnew => scheduled
2012-05-24 20:38ioritzCiafix_in_branch => pi
2012-05-28 13:25hgbotCheckin
2012-05-28 13:25hgbotNote Added: 0049364
2012-05-28 13:25hgbotStatusscheduled => resolved
2012-05-28 13:25hgbotResolutionopen => fixed
2012-05-28 13:25hgbotFixed in SCM revision => http://code.openbravo.com/erp/devel/pi/rev/375e1e6675af03e756925475249ff2cc33627e44 [^]
2012-05-29 03:27hudsonbotCheckin
2012-05-29 03:27hudsonbotNote Added: 0049391
2012-05-29 18:43VictorVillarNote Added: 0049443
2012-05-29 18:43VictorVillarStatusresolved => closed

Notes
(0049364)
hgbot   
2012-05-28 13:25   
Repository: erp/devel/pi
Changeset: 375e1e6675af03e756925475249ff2cc33627e44
Author: Ioritz Cia <ioritz.cia <at> openbravo.com>
Date: Mon May 28 10:26:48 2012 +0200
URL: http://code.openbravo.com/erp/devel/pi/rev/375e1e6675af03e756925475249ff2cc33627e44 [^]

Fixes issue 20305: table MA_sequence_machine has not assigned a window.

---
M src-db/database/sourcedata/AD_TABLE.xml
---
(0049391)
hudsonbot   
2012-05-29 03:27   
A changeset related to this issue has been promoted main and to the
Central Repository, after passing a series of tests.

Promotion changeset: https://code.openbravo.com/erp/devel/main/rev/ced2fdfb9aee [^]

Maturity status: Test
(0049443)
VictorVillar   
2012-05-29 18:43   
Verified