0016696: Callout not working: SL_Internal_Consumption_Product
The callout linked to m_product_id column in M_Internal_ConsumptionLine table is not working.

It is possible related to the fact that it has an EXECUTE command on it.

This issue is not reproducible in Openbravo 2.50.

It is reproducible in the new layout and in the classic mode as well.
Go to: Production Management || Transactions || Internal Consumption

Fill the header.
Go to lines.
Select Beer as product. UOM is units.
Select Plain Water. Liter should be the unit, but it is not changed.

As the UOM is a read only field, it is not possible to change it manually.
No tags attached.
duplicate of defect 0015914 closed jonalegriaesarte Bad behaviour when select a product in Internal Consumption 
related to defect 00164923.0RC7 closed iperdomo It is not possible to use 'EXECUTE' command in callouts in Openbravo 3 
Issue History
2011-04-07 15:14AinhoaPagolaNew Issue
2011-04-07 15:14AinhoaPagolaAssigned To => alostale
2011-04-07 15:14AinhoaPagolaModules => Core
2011-04-07 15:15AinhoaPagolaRelationship addedrelated to 0016492
2011-04-11 10:26alostaleStatusnew => scheduled
2011-04-11 10:26alostaleAssigned Toalostale => iperdomo
2011-04-11 10:26alostalefix_in_branch => pi
2011-04-18 18:19AinhoaPagolaRelationship addedduplicate of 0015914
2011-04-18 18:20AinhoaPagolaStatusscheduled => closed
2011-04-18 18:20AinhoaPagolaResolutionopen => duplicate
2011-04-19 00:00anonymoussf_bug_id0 => 3289081